TM 10-5411-206-14
Table 2-1. Operator Preventive Maintenance Checks and Services (cont).
B Before
D During
A After
W Weekly
M Monthly
Item
No.
4
5
6
7
8
9
10
B
Interval
D
A W M
Item to be
Inspected
Door Assembly
(cont)
Lifting and Towing
Eye Assemblies
Roof Access Steps
Roof Handle
Drain Plug
RFI/EMI
Components
(S-280B/G
Shielded)
Wall, Floor and
Ceiling Panels
Procedures
Check for and have repaired
or adjusted as necessary
d. Check door surfaces for punctures.
e. Make sure weather gaskets are in good
condition.
a. Inspect for excessive wear.
b. Inspect for rust, loose or missing
hardware.
c. Make sure rings and pins rotate freely.
a. Make sure steps stay in up or down
position as required.
b. Check for loose or missing
hardware.
Check for loose or missing hardware.
Make sure drain plug is in place.
a. Inspect metal door gaskets.
b. Inspect filter.
c. Check for presence of drain plug
washer, keeper shims and hinge shims.
Inspect for punctures and delamination.
Item is
Not Ready/
Available If:
Drain plug is
missing (shielded
shelters).
a. One or both
gaskets are miss-
ing or damaged.
b. Filter is dam-
aged or missing.
c. A washer or
shim is missing.
Punctures are
present.
2-3