TM 10-5411-206-14
Table 3-1. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. DOOR DOES NOT OPEN OR CLOSE SMOOTHLY
Step 1. Inspect hinges for inadequate lubrication.
Lubricate as required (para 3-1).
Step 2. Notify higher level of maintenance.
2. DOOR DOES NOT STAY OPEN
Step 1. Check to see if door brace catch is missing or improperly installed.
Install catch (para 3-11).
Step 2. Check to see if door brace assembly is detached from door or door stop angle.
Replace missing hardware (para 3-11).
3. DOOR HANDLE IS JAMMED OR DOES NOT OPERATE SMOOTHLY
Step 1. Inspect components for inadequate lubrication.
Lubricate as required (para 3-1 ).
Step 2. Inspect door handle and latching mechanism for missing or damaged components.
Repair or replace components as required (para 3-15).
4. WATER IS GETTING INTO SHELTER
Step 1. Inspect shelter walls and ceiling for punctures.
Patch any holes (para 3-9.c).
Step 2. Check to see if roof access steps or d-ring hand holds have pulled away from shelter wall.
Apply sealer to gaps around step flange, or replace step (para 3-17) or d-ring
(para 3-18).
Step 3. Notify higher level of maintenance.
3-6