TM 10-5411-206-14
Table 3-1. Troubleshooting (cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. THERE IS EVIDENCE OF RADIO FREQUENCY/ELECTROMAGNETIC INTERFERENCE (S-280 B/G
SHIELDED)
Step 1. Check for missing latch keeper shims.
Install shims (para 3-15).
Step 2. Check for missing drain plug washer.
Install washer (para 3-19).
Step 3. Notify higher level of maintenance.
Section V. UNIT
Subject
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Repair Procedures . . . . . . . . . . . . . . .
Touchup Painting . . . . . . . . . . . . . . . . . . . . . . .
Door Brace Assembly . . . . . . . . . . . . . . . . . . . .
Door Assembly . . . . . . . . . . . . . . . . . . . . . . . . .
Emergency Exit Panel Assembly . . . . . . . . . . .
T-Latches and Holders . . . . . . . . . . . . . . . . . . .
Door Latch Assembly . . . . . . . . . . . . . . . . . . . .
Air inlet Filter . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recessed Step Pan Assemblies . . . . . . . . . . . .
D-Ring Assemblies (Hand Holds) . . . . . . . . . . .
Drain Plug and EMI Washer . . . . . . . . . . . . . . .
RFI/EMI Components . . . . . . . . . . . . . . . . . . . .
MAINTENANCE
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
PROCEDURES
Para
. . . . . . . . . . . . . . . . . . 3-8
. . . . . . . . . . . . . . . . . . 3-9
. . . . . . . . . . . . . . . . . . 3-10
. . . . . . . . . . . . . . . . . . 3-11
. . . . . . . . . . . . . . . . . . 3-12
. . . . . . . . . . . . . . . . . . 3-13
. . . . . . . . . . . . . . . . . . 3-14
. . . . . . . . . . . . . . . . . . 3-15
. . . . . . . . . . . . . . . . . . 3-16
. . . . . . . . . . . . . . . . . . 3-17
. . . . . . . . . . . . . . . . . . 3-18
. . . . . . . . . . . . . . . . . . 3-19
. . . . . . . . . . . . . . . . . . 3-20
Page
3-7
3-8
3-17
3-18
3-21
3-22
3-23
3-24
3-30
3-31
3-32
3-34
3-35
3-8. General. This section contains maintenance procedures which are the responsibility of unit maintenance,
as authorized by the Maintenance Allocation Chart (appendix B). Since most shelters contain sensitive electronic
equipment that cannot be easily removed, unit level maintenance and repair will primarily involve shelter exteriors
or easily accessible interior areas, unless floors, ceilings or walls have evidence of water intrusion which can
jeopardize operation of the equipment. The shelters shall be returned to the depot for repair if any of the following
conditions exist:
a. Panel damage spans a structural member.
b. Replacement of an entire wall, ceiling or floor is required.
c. Extensive equipment removal beyond the capability of the using unit is required.
3-7