TM 10-5411-207-14
3-18.
Door Assembly (cont).
e.
Disassemble. (Figure 3-20)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Turn each of the four knob assemblies (1) counterclockwise to release the
emergency exit panel (2) and remove panel from door (3).
Remove rivet (4) attaching the knob assembly chain (4) to retainer bracket (5)
and remove knob. Refer to paragraph 3-9.a. for rivet removal.
Remove two rivets (6) attaching each air inlet panel retainer (5) to door panel
(2) and remove retainers.
Remove 17 rivets (7) attaching the drip moulding (9) to door and remove drip
moulding (9) and drip cap strip (8).
Remove and retain four phillips head screws (10), flat washers (11), lock
washers (12), and nuts (13) attaching each T-latch holder (14) to door (3) and
remove holder (14).
Remove the silicone weather gasket (15) and clean any adhesive residue from
track.
(Shielded) Remove the EM shield (15.1).
f. A s s e m b l e . ( F i g u r e 3 - 2 0)
(1)
(2)
(3)
(4)
(5)
C A U T I O N
Allow at least 30 minutes cure time for adhesive before using door.
Apply RTV 138 silicone sealer in track groove all around door and snap new
gasket (15) in place in track on door (3).
(Shielded) Clean the EM shield track of any dirt, place a new shield (15.1) over
the track and snap into place.
N O TE
Dip screws in sealer prior
Position T-latch holder (14) in place on
to installation.
door panel (3) and secure with four
phillips head screws (10), flat washers (11), lock washers (12), and nuts (13).
Place drip moulding (9) and drip cap strip (8) on door and secure with 17 blind
rivets (7).
Position each air inlet panel retainer (5) in place on inside of door and secure to
door with four blind rivets (6).
Change 2
3-35