TM 10-5411-206-14
(8) Position retaining strips (4 and 5) on flange of intake louver assembly (3) so that previously installed
corner screws (2) pass through end mounting holes of each retaining strip.
(9) Working on inside of emergency exit, install remaining slotted screws (2).
(10) Apply a bead of sealer around edge of flanges of intake Iouver assembly (3) and RFI/EMI filter (6).
(11) Close emergency exit cover (l).
NOTE
FOLLOW-ON MAINTENANCE: Install air inlet filter (para 3-16).
Figure 4-7. Intake Louver Assembly and RFI/EMI Filter Replacement.