TM 5-6350-280-23&P
4.6.4 Power Cord Assembly Maintenance.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Material/Parts
Electronic System Maintenance Tool Kit
Power Cord Assembly (Appendix C,
(Appendix B, Section III, item 1)
figure 5, item 3)
Equipment Conditions
General Safety Instructions
Equipment shutdown (TM 5-6350-280-10)
Do not work on equipment without
Drawer Assembly open and EMI shield
following standard shop safety
removed paragraph 4.6.3
precautions.
4.6.4.1 Removal.
WARNING
Do not work on CMA with 120 Vac power on. Always work with another person
nearby who is familiar with hazards of electronic equipment and is competent in
administering first aid. Failure to obey this warning could result in death or injury.
a.
Unlock and open rear access door.
b.
Unplug power cord assembly from multiple outlet strip.
c.
Tag and disconnect power cord assembly from DC power supply in CMA.
d.
Remove power cord assembly.
4.6.4.2 Installation.
a.
Connect power cord assembly to DC power supply in CMA and remove tags.
b.
Plug power cord assembly into multiple outlet strip and remove tags.
c.
Close and lock rear access door.
d.
Install EMI shield and close drawer assembly, paragraph 4.6.3. Refer to TM 5-280-6350-10 and power on
equipment.
4.6.5 RX-TX Cable Assembly Maintenance.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Material/Parts
Electronic System Maintenance Tool Kit
RX-TX Cable Assembly (Appendix C,
(Appendix B, Section III, item 1)
figure 5, item 4)
Equipment Conditions
General Safety Instructions
Equipment shutdown (TM 5-6350-280-10)
Do not work on equipment without
Drawer Assembly open and EMI shield
following standard shop safety
removed paragraph 4.6.3
precautions.
4-33