TM 5-6350-280-23&P
4.6.3.1 Removal.
WARNING
Do not work on CMA with 120 Vac power on. Always work with another person
nearby who is familiar with hazards of electronic equipment and is competent in
administering first aid. Failure to obey this warning could result in death or injury.
a.
Remove four screws (1), lock washers (2), and washers (3) from drawer assembly (4).
b.
Pull drawer assembly (4) outward until catches (5) engage.
c.
Unlock and open rear door.
d.
Tag and disconnect power cord from DC power supply.
e.
Remove four screws (6) and lock washers (7) from EMI shield (8) on drawer assembly.
f.
Remove EMI shield (8).
g.
Tag and disconnect RX-TX cable assembly (9) from backplanes.
h.
Tag and disconnect two Area Input cable assemblies (10) from backplanes.
i.
Release catches (5) and pull outward on drawer assembly until clear of slides.
4.6.3.2 Installation.
WARNING
Do not work on CMA with 120 Vac power on. Always work with another person
nearby who is familiar with hazards of electronic equipment and is competent in
administering first aid. Failure to obey this warning could result in death or injury.
a.
Align drawer assembly (4) with slides.
b.
Push on drawer assembly (4) keeping slides aligned until catches (5) engage.
c.
Connect RX-TX cable assembly (9) to backplanes and remove tags.
d.
Connect two Area Input cable assemblies (10) to backplanes and remove tags.
e.
Install four lock washers (7) and screws (6) to secure EMI shield (8) on drawer assembly.
f.
Connect power cord assembly on the DC power supply and remove tags.
g.
Release catches and slide drawer assembly (4) inward until flush with cabinet assembly.
h.
Install four flat washers (3), lock washers (2), and screws (1).
i.
Refer to TM 5-6350-280-10 and power on equipment.
4-32