3-15.
Drain Plug (cont).
(5) Position plate (2) with the chamfer facing down over the drain hole on the
underside of the floor panel and secure using four rivets (1).
(6) Insert drain tube (3) in hole and flare the end of the tube touching the plate (2)
against the chamfer of the plate (2).
(7) Place drain plug (5) in drain and secure drain plug chain with rivet (4) to pan (7).
(8) Apply sealer to joints, edges and joining surfaces of the pan, tube, and plate.
Figure 3-14. Drain Replacement.
3-26 Change 1