TM 10-5411-207-14
3-19.
Emergency Exit Panel Assembly (cont).
(8)
(9)
(10)
(11)
Clean adhesive residue from gasket tracks in panel and cover, and apply RTV
138 silicone sealer in track grooves.
CAUTION
Allow at least 30 minutes cure time for the silicone sealer to
adhere before using the panel.
Snap new silicone gaskets (1 and 2) in track on panel and cover flanges.
(Shielded) Clean EM shield track of any dirt, place a new shield (1.1) over the
track and snap in place.
Apply sealer over retaining strips (18 and 19), screw ends (16), flange of louver
(17) and edge of (Shielded) RFI/EMI filter flange (17.1).
CAUTION
Leave the exit panel assembly in a horizontal position after
application of sealer, until sealer is no longer tacky to the touch
(2-3 days).
f. Install. (Figure 3-20)
(1) Position emergency exit panel (2) in opening of door.
(2) Turn four knobs (1) clockwise to secure emergency exit panel (2) to door (3).
3-42
Change 2