4.6.10.1 Removal.
4.6.10.1 Removal.
WARNING
· High Voltage is used in the operation of this equipment. Serious injury or death
may result if personnel fail to observe safety precautions. Remove all jewelry
from fingers, wrists, and neck before working on live electrical components.
· Do not work on CMA with 120 Vac power on. Always work with another person
nearby who is familiar with hazards of electronic components and is competent
in administering first aid. Failure to obey this warning could result in death or
injury.
a.
Remove protective cover (7).
b.
Tag and disconnect wires (2) from power supply (3).
NOTE
Only remove data receiver A4 and CPU cards that prevent accessing power supply
assembly mounting screws.
c.
Remove four screws (4), lock washers (5), and flat washers (6) that secure DC Power Supply (3) to drawer
assembly.
d.
Remove Power Supply (3) from drawer assembly.