TM 5-6350-280-23&P
4.6.11.1 Removal.
WARNING
Do not work on CMA with 120 Vac power on. Always work with another person
nearby who is familiar with hazards of electronic equipment and is competent in
administering first aid. Failure to obey this warning could result in death or injury.
a.
Remove six screws (1), flat washers (2), and lock washers (3).
b.
Remove Surge Suppressor CCA (4).
4.6.11.2 Installation.
a.
Align mounting holes on Surge Suppressor CCA (4) with mounting holes on door.
b.
Install six lock washers (3), flat washers (2), and screws (1).
c.
Install twisted pairs, paragraph 4.6.2 and Area Input Cable Assembly to surge suppressor CCA, paragraph 4.6.6.
4.6.12 Input/Output CCA Maintenance
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Material/Parts
Electronic System Maintenance Tool Kit
Input/Output CCA (Appendix C, figure 3,
(Appendix B, Section III, item 1)
item 11)
Equipment Conditions
General Safety Instructions
Equipment shutdown (TM 5-6350-280-10)
Do not work on equipment without
Rear access door open
following standard shop safety
precautions.
4-45